Armored Thermal Resistance of Temperature Transmitter

  • Brand   HS
  • Type   Armored Thermal Resistance of Temperature Transmitter
Introduction

Armored Thermal Resistance of Temperature Transmitter

Armored Thermal Resistance is usually matching with display instrument, memorizing meter, electronic computer . Directly measure hydrocarbons which may cause explode 0 ~ 500 ℃ about liquid, steam,gas and surface temperature of solid medium at the production site .

Principle of Armored Thermal Resistance for Temperature Transmitter

Resistance under the action of temperature thermal resistance wire change. Display instrument will indicate the resistance heat resistance value generated by the value of the corresponding temperature.

Main Technical Parameters of Armored Thermal Resistance

Thermal resistance temperature sensor at 100 ℃ resistance value (R100) and at 0 ℃ resistance value (R0) ratios of R100/ R0.

Indexing of Pt100: a R0 = 100 ± 0.06.

B R0 = 100 ± 0.12.

W100 = R100/ R0 = 1.3850

Range specifications of Armored Thermal Resistance

Model number

Division No.

The measuring range

accuracy class

The allowable deviation

hs

Pt100

200500

A

200 ~ 650   ± (0.15 + 0.002 - t -)

B

200 ~ 800 ± (0.30 + 0.005 - t -)


More Products