The high performance Yokogawa EJA210A and EJA220A flange mounted differential pressure transmitter can be used to measure levels of densities of solidifying or precipitating liquids. Both output a 4 to 20 mA DC signal corresponding to the measured differential pressure. The Yokogawa EJA Series is available with BRAIN, HART, FOUNDATION™ fieldbus or PROFIBUS PA communication protocols.
Features of Yokogawa EJA210A and EJA220A Flange Mounted Differential Liquid Level Pressure Transmitter
Excellent performance and stability
The EJA210A and EJA220A liquid level transmitter uses a silicon resonant sensor formed from monocrystal silicon, a perfect material which has no hysteresis in pressure or temperature changes. The sensor minimizes overpressure, temperature change, and static pressure effects, and thus offers unmatched long-term stability.
Compact and light-weight design
Half the weight of conventional models thanks to miniaturization of the casing with the amplifier ASIC, pressure cell structure, and flange. The ASIC uses the minimum number of parts and improves the reliability of the amplifier.
Fieldbus communication capability
Fieldbus is a digital two-way communication system. It is a revolutionary technology for configuring instrumentation control systems and a promising successor to the standard 4 to 20 mA analog communication used in most field instruments today.
EJA series offers two types of fieldbus models, FOUNDATION™ fieldbus Low Voltage Mode and PROFIBUS PA devices, which ensure interoperability between Yokogawa and other manufactures. As for software, the EJA series incorporates two AI function blocks that compute differential and static pressures to allow flexible configuration of instrumentation.
Specifications of Yokogawa EJA210A and EJA220A Flange Mounted Differential Pressure Transmitter
|
Yokogawa EJA210A / EJA220A |
|
M Capsule |
H Capsule |
|
Range |
-100 to 100 kPa |
-500 to 500 kPa |
Span |
1 to 100 kPa |
5 to 500 kPa |
Accuracy |
±0.2% |
±0.2% |
Degrees of protection |
IP67, NEMA 4X, and JIS C0920 immersion proof |
|
Certificates |
FM, CENELEC ATEX, CSA, IECEx |
|
Output |
4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication |
|
Supply voltage |
BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) |
|
Ambient temperature |
-40 to 85 deg C (-40 to 185 deg F) (general use type) |
|
Process temperature |
-40 to 120 deg C (-40 to 248 deg F) (general use type) |
|
Maximum working pressure |
Flange rating pressure |
|
Mounting |
Flange mounting |
|
Process flange size |
EJA210A: 3-inch (80mm), 2-inch (50mm) |
|
Diaphragm material |
SUS316L, Hastelloy C-276, Tantalum |
|
Process flange material |
S25C, SUS304, SUS316 |
|
Housing |
Cast aluminum alloy or SUS316 equivalent stainless steel (optional |