qualitydress.com
Xian Yunyi Instrument Co., Ltd.
Xian Yunyi Instrument Co., Ltd. Our slogan is zero fault in production
Home > Temperature Measuring Instruments >

High performance Single or Dual sensor input 3144P Temperature Transmitter

High performance Single or Dual sensor input 3144P Temperature Transmitter

Place of Origin : China or USA
Brand Name : Rosemount
Certification : SAA,CSA,FM, IECEx, INMETRO Intrinsic Safety TIIS Flameproof, China Intrinsic Safety, China Flameproof
Model Number : 3144P
MOQ : 1pc
Price : USD510~USD610
Packaging Details : In carton or as customer’s requirement
Delivery Time : 6~8weeks
Payment Terms : T/T, L/C, PayPal, Western Union, Cash, Escrow
Supply Ability : 1000 pcs

3144P Temperature Transmitter used in critical control and safety applications with single sensor or dual sensor inputs


Quick Detail:

· 3 analog inputs and 1 input selector

· Single or Dual sensor input

· ±0.18°F for Pt100 RTD

· 2-, 3- and 4-wire RTDs, thermocouple, millivolt and ohm Inputs

· FOUNDATION fieldbus Output

· 9.0 to 32V dc, 11 mA max supply voltage

· Sensor Drift Alert - alarms user to unreliable measurement

· Dual-compartment housing providing isolation between electronics and terminal compartments


Description:

The Rosemount 3144P temperature transmitter provides superior accuracy, stability, and reliability – making it the industry-leading temperature transmitter used in critical control and safety applications. The Rosemount 3144P temperature transmitter is available with either 4-20 mA/HART or a completely digital FOUNDATION fieldbus protocol. It has the capability to accept either single-sensor or dual-sensor inputs. This dual sensor input capability allows the transmitter to accept simultaneous input from two independent sensors, enabling measurement of differential temperatures, averaging temperature or redundant temperature measurement.

The Rosemount 3144P temperature transmitter can be configured for a variety of sensor inputs: RTD, thermocouple, millivolt, or ohm. The HART version of the Rosemount 3144P temperature transmitter is approved for use in Safety Instrumented Systems. (Third party validated metrics are available for the 3144P. Testing done per IEC 61508 for Safety Instrumented Systems).

The Rosemount 3144P temperature transmitter's Transmitter-Sensor Matching feature eliminates interchangeability error, which improves accuracy by 75%. Sensor Drift Alert enables continuous monitoring of the differential temperature for two sensors. When one sensor drifts, the differential of the sensors will increase. If this difference exceeds defined limits, the user is alerted of an unreliable measurement. The Hot Backup feature can reduce the risk of losing important temperature measurements by 80% when the measurement automatically switches to the backup sensor if the primary sensor fails.

Meeting the NAMUR NE 21 recommendations, the Rosemount 3144P temperature transmitter ensures top transmitter performance in harsh EMC environments. In addition, the HART Rosemount 3144P temperature transmitter meets NAMUR NE 43 and NE 89 recommendations.

High performance and advanced diagnostics are available with HART or FOUNDATION fieldbus communication. Rosemount 3144P temperature transmitters offer diagnostics that provide continuous measurement status (good, bad, or uncertain), as well as sensor failure indication. Both transmitters provide performance information to AMS.

Local indication of temperature measurement and diagnosits provides immediate and accurate verification of process conditions. The Rosemount 3144P temperature transmitter is capable of single-sensor or dual-sensor input. This also allows for configuration of differential or average temperature measurements.


Applications:

* Temperature Field Transmitter with HART-protocol convert various input signals into a scalable 4 to 20mA analogue output signal
* Input
Resistance thermometers(RTD)
Thermocouples(TC)
Resistance transmitters(ohm)
Voltage transmitters(mV)



Specifications:

Digital Accuracy±0.10° C (±0.18° F) for Pt100 RTD
D/A Accuracy±0.02% of span (Applies to HART/4-20 mA devices)
Ambient Temperature Effects0.0015 °C (+0.001% of span for HART/4-20 mA devices) per 1.0 °C (1.8 °F) change in ambient for a Pt100 RTD
Stability (RTDs)±0.1% of reading or 0.1° C, whichever is greater, for two years
±0.25% of reading or 0.25° C, whichever is greater, for five years
InputTwo Independently Configured Inputs; 2-, 3-, and 4-wire RTD, and Ohm, Thermocouple, Millivolt
Output4-20 mA/HART or FOUNDATION fieldbus signal
Supply Voltage12.0 to 42.4 V dc (with 250 ohm load, 18.1 V dc is required)








Competitive Advantage:

Universal Temperature Transmitter with HART-protocol for converting various input signals into a scalable 4 to 20mA analogue output signal.

Performance
*Universally progammable with HART-protocol for various input signals
*Two-wire technology, analogue output 4 to 20mA
*Highly accurate in entire operating temperature range
*Wide voltage supply range
*Customer specific measurement range settings
*Simple and user friendly software
*Multiparametric backlight rotatable LCD display






















































Product Tags:

Temperature transmitter

      

4-20ma temperature transmitter

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

High performance Single or Dual sensor input 3144P Temperature Transmitter Images

Send your message to this supplier
 
From:
To: Xian Yunyi Instrument Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
var guid_default="c1564a1f4152179fcc2c53785371269d";