Quick Detail:
• Combines the Rosemount 3095 MultiVariable
mass flow transmitter with the Rosemount 485 Annubar Primary
• 0.90% of mass flow rate accuracy
• Measures differential pressure, static pressure,
and process temperature with a single pipe penetration
• Dynamically calculates compensated mass flow
• Ideal fluid types: gas and steam
Description:
Better measurement begins by selecting the best flow technology for
each application. Annubar® technology has been specified for over
35 years in applications requiring performance, flexibility,
reliability and lower total cost of ownership. The innovative
technology of the Annubar sensors offers more advantages that save
time and money.
Rosemount 3095MFA mass ProBar flowmeter concentrated with both the advantage of Roemount 485 AnnuBar sensor and Rosemount 3095 MultiVariable transmitter. It accurately measures static press, temperature, differential pressure by an uniparted pipeline perforation, meanwhile, it calculates dynamic compensation mass flow rate. Rosemount 3095MFA mass ProBar works out better accuracy in a wider flow ratio of measuring range to compare with the traditional differential pressure technology, supplying the most developped method of flow rate measurement.
Individual device measures three variable: by an uniparted pipeline perforationto measure continually differential pressure, pressure and process temperature.
Mass flow rate output: calculate dynamic compensation mass flow rate.
Easy configuration: by using engineering assistant can easily achieve synthesized configuration, maintenance and diagnosis.
Integrative measurement of temperature: AnnuBar sensor integrates RTD by hermetic thermocouple casing, dismantling without turning off the system.
Reduce whole installation cost: not three but one instrument can achieve easy installation and lessen maintenance cost.
Applications:
Annubar Flowmeter Series: Rosemount 3051SFA
ProBar®, 3095MFA Mass ProBar®, 485, and 285
The state-of-the-art, fifth generation Rosemount 485 Annubar
combined with the 3051S or 3095 MultiVariable transmitter creates
an accurate, repeatable and dependable insertion-type flowmeter.
The Rosemount 285 provides a commercial product offering for
your general purpose applications.
Specifications:
General Specifications | |
Accuracy | +/- 0.9% of mass flow rate for gas and steam |
Turndown | 8:1 |
Output | 4-20mA signal based on HART® Communication |
Sensor Material | 316 Stainless Steel or Hastelloy® C-276 |
Mounting Options | Pak-Lok, Flanged with opposite side support, Flange-Lok, Threaded Flo-Tap, and Flanged Flo-Tap (note: Manual and Gear Drives are available for both of the Flo-Tap mounting styles) |
Line Size | 2-in. to 8-in. (50 to 200 mm) – Sensor Size 1 6-in. to 36-in. (150 to 900 mm) – Sensor Size 2 12-in. to 72-in. (300 to 1800 mm) – Sensor Size 3 |
Competitive Advantage:
· Industry leading integrated DP Flowmeters
· Energy Savings gained through minimal permanent pressure loss
· Real-time mass and energy flow measurements available with integral temperature design
Flo-tap design of the 485 and 585 allow installation without system shutdown
Mass ProBar Rosemount Annubar Flowmeter 3095MFA with better accuracy Images |