qualitydress.com
Xian Yunyi Instrument Co., Ltd.
Xian Yunyi Instrument Co., Ltd. Our slogan is zero fault in production
Home > Differential Pressure Transmitter >

Yokogawa EJA110A differential pressure transducer

Yokogawa EJA110A differential pressure transducer

Brand Name : Yokogawa
Model Number : EJA110A
Certification : FM, CENELEC ATEX, CSA, IECEx
Place of Origin : China or Japan
MOQ : 1pc
Payment Terms : T/T, L/C, PayPal, Western Union, Cash, Escrow
Supply Ability : 100pcs
Delivery Time : 3weeks
Packaging Details : In carton or as customer’s requirement
Bolting : SCM435, SUS630, or SUH660
Reference Accuracy : 0.065%
Housing : Low copper cast-aluminum alloy with polyurethane paint
Degrees of Protection : IP67, NEMA4X
Supply Voltage : 10.5 to 42 V DC
Process Connector Gasket : PTFE Teflon
Cover O-rings : Buna-N, fluoro-rubber (optional)
Fill Fluid : Silicone, Fluorinated oil (option)

Yokogawa EJA110A differential pressure transducer


Quick Detail:


The EJA-A series is Yokogawa's most successful pressure transmitter line. First released in 1991, it continues to offer high performance and high reliability for any application. With an installed base of over 4-1/2 million EJA-A transmitters worldwide, it has a proven track record that makes it a true industry workhorse.

The EJA110A is the Traditional-mount Differential Pressure Transmitters in the series.

EJA110A features include:

0.065% Accuracy

0.1% Stability per 5 years

2,300 psi MWP


Description:


Yokogawa's Differential Pressure Transmitter with DPharp digital sensor offers the performance and device intelligence needed to get greater insight into your process.


Plants run better with Yokogawa pressure transmitters.


Yokogawa's DPharp active sensor and rugged construction allow users to run their plants safer and with less downtime.

Yokogawa Pressure transmitter help plants run longer.

Rugged Construction


Accessories

3rd Party Manifolds


Applications:


Boiler and Feedwater Pump Efficiency Optimization

The primary function of a utility boiler is to convert water into steam to be used by a steam turbine / generator in producing electricity. The boiler consists of a furnace, where air and fuel are combined and burned to produce combustion gases, and a feedwater tube system, the con- tents of which are heated by these gases.


Hydrogen Permeation

Hydrogen is the simplest and smallest atomic element. Water, acids, bases, and the immense family of organic compounds all contain hydrogen. Even though hydrogen is not corrosive, it can cause problems for pressure transmitters through Hydrogen Permeation.

Industry: Water& Wastewater


Reverse Osmosis Filter Monitoring

The reverse osmosis (RO) process is used in many industries. This process uses membrane separation which has been proven to be one of the most economical means to remove suspended solids from feed water.

Industry: Water& Wastewater


Screen Differential Control

What is screen differential control? This is a control application commonly found at utility plants located on rivers, lakes and other large bodies of water and at industrial facilities where a large amount of cooling water is used. Screen differential control and monitoring is needed to prevent damage to rotating screens caused by excessive pressure being applied by debris collecting on the screens.

Industry: Water& Wastewater


Specifications:


Yokogawa EJA110A Differential Pressure Transmitter

M Capsule

H Capsule

Range

-100 to 100 kPa
(-400 to 400 inH2O)

-500 to 500 kPa
(-2000 to 2000 inH2O)

Span

2.5 to 100 kPa
(10 to 400 inH2O)

25 to 500 kPa
(100 to 2000 inH2O)

Accuracy

±0.2%

±0.2%

Degrees of protection

IP67, NEMA 4X, and JIS C0920 immersion proof

Certificates

FM, CENELEC ATEX, CSA, TIIS, IECEx

Output

4 to 20 mA DC or FOUNDATION fieldbus or PROFIBUS PA 2-wire system

with digital communication

Supply voltage

BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model)

Ambient temperature

-40 to 60 deg C (-40 to 140 deg F) (general use type)
-30 to 60 deg C (-22 to 140 deg F) (with integral indicator)
It must be within the fill fluid operating temprature range

Process temperature

-50 to 300 deg C (-58 to 572 deg F)
It must be within the fill fluid operating temprature range

Maximum working pressure

Flange rating pressure

Mounting

Transmitter: 2-inch pipe mounting
Diaphragm seals: flange mounting

Process flange size

Flush type: 3-inch(80mm), 2-inch(50mm)
Extended type: 4-inch(100mm), 3-inch(80mm)

Combination type:

4-inch(100mm) for extended high side,
3-inch(80mm) for flush low side

Diaphragm material

SUS316L, Hastelloy C-276, Tantalum, Titanium

Process flange material

S25C, SUS304, SUS316

Housing

Cast aluminum alloy or SUS316 equivalent stainless steel (optional)


Competitive Advantage:


Differential pressure transmitters, which serve as the core of field instrumentation, are widely used to measure the flow rate, pressure and density of liquids, gases and steam, as well as the level of liquid in a tank.



Product Tags:

Rosemount pressure transmitter

      

Rosemount differential pressure transmitter

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Yokogawa EJA110A differential pressure transducer Images

Send your message to this supplier
 
From:
To: Xian Yunyi Instrument Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
var guid_default="5c3d25e6e402ca8b8472b59811ab9951";