Quick Detail:
· Industry leading integrated DP Flowmeters
· Energy Savings from minimal permanent pressure loss
· 2" to 96" line sizes
· Various mounting options
· Real-time mass and energy flow measurements
· Flo-tap design of the 485 and 585
Description:
The Rosemount 3051CFA Annubar Flowmeter combine the proven 3051C
pressure transmitter and the latest primary element technology:
· Annubar averaging pitot tube
· Compact conditioning orifice plate
· Integral orifice plate
Better measurement begins by selecting the best flow technology for
each application. Annubar® technology has been specified for over
35 years in applications requiring performance, flexibility,
reliability and lower total cost of ownership. The innovative
technology of the Annubar sensors offers more advantages that save
time and money.
Multivariable capabilities allow for real time fully compensated
mass and energy flow. The 3051CFA minimizes permanent pressure loss
and saves energy with annubar technology. It reduces straight pipe
requirements to two diameters upstream and downstream from flow
disturbances with conditioning orifice plate technology. It
improves accuracy and repeatability in small line sizes with a
integral orifice plate technology.
Applications:
The Rosemount 3051CFA Annubar Flowmeter utilizes the patented
T-shaped sensor
design that delivers best in class accuracy and performance. Main
Capabilities include:
while meeting the needs of diverse process applications, whether it
is high accuracy
for precision control or high strength for severe flow
applications.
Specifications:
Accuracy | •Mass flow up to 0.8% of mass flow rate, 14:1 turndown •Classic MV up to ±0.85 % of flow rate, 8:1 flow turndown | •Volumetric flow up to 0.8% of volumetric flow rate, 14:1 turndown •Classic MV up to ±0.85% of volumetric flow rate, 8:1 turndown |
Repeatability | ± 0.1 % | ± 0.1 % |
Output | •4-20mA signal based on HART® Communication •WirelessHART with Smart Wireless THUM adapter | •4-20mA signal based on HART® Communication •WirelessHART •FOUNDATION™ fieldbus |
Long Term Stability | Up to 10-year stability | Up to 10-year stability |
Warranty | Up to 12-year limited warranty | Up to 12-year limited warranty |
Diagnostics | •User-writable process temperature sensor limits •Sensor Temperature as an output •Instant Flow Verification | Advanced HART Diagnostic Suite |
Line Size | 2-in. to 8-in. (50 to 200 mm) – Sensor Size 1 6-in. to 36-in. (150 to 900 mm) – Sensor Size 2 12-in. to 72-in. (300 to 1800 mm) – Sensor Size 3 | 2-in. to 8-in. (50 to 200 mm) – Sensor Size 1 6-in. to 36-in. (150 to 900 mm) – Sensor Size 2 12-in. to 72-in. (300 to 1800 mm) – Sensor Size 3 |
Competitive Advantage:
· Industry leading integrated DP Flowmeters
· Energy Savings from minimal permanent pressure loss
· 2" to 96" line sizes
· Various mounting options
· Real-time mass and energy flow measurements
· Flo-tap design of the 485 and 585
Rosemount 3051CFA Annubar Flowmeter Combine the proven 3051C pressure transmitte Images |